Image is for illustration only and should not be relied upon
Potterton (Potterton Myson) EP2 Programmer
£106.97
Ex VAT: £89.14
- Digital Clock Display
- Independent 7 Day Programming for Heating and Hot Water
- LED Circuit Indicators
- Built In Programme
- Clock Maintained During Power Failure
- Individual Over-rides
- Fully Pumped or Gravity Systems
Replaces (Same Backplate and Wiring for Easy Swap):
Potterton EP2000, EP2001, EP2002, EP3000, EP3001, EP3002, EP6000, EP6001, EP6002
Ask a Question about Potterton (Potterton Myson) EP2 Programmer
-
The Potterton EP2 does not actually have a button labeled STEP. To step through your heating and hot water time profiles, pull down the hinged panel on the front of the unit. You will use the SELECT button (along with the + and - buttons and the SET slider) located under the panel to move through each ON and OFF time setting.
-
The imprinted clock faces and "ABS" lettering on the inside of the door are standard plastic manufacturing and material identification markings
-
Yes, this will be a direct replacement.
-
Yes, you can cancel the advance by pressing it again.
-
Choose ID number 4,5,6,10,11 or 12 when applying power to the programmer. Please see the instructions (section 11) for more details.
-
If you have 1 or more motorised valves on your system, then you need to choose a pumped option.
Gravity systems are very rare now.
-
Yes, the H/W is for Heating/Water - not Hot Water.
-
No wiring changes are needed at all.
Is the bright blue display meant to be on all the time? Also can the brightness be changed?
Answers1
-
Yes. It is not adjustable.
-
Hi. Yes, it would be a straight swap.
-
Hi
If you have one or more motorised valves, then it is a fully pumped system. Fully pumped has been standard now for 20 years.
-
Hi. It comes complete with a battery.
-
Yes it is. A simple swap.
-
It is under the flap to the left of the screen.